TEAM PRODUCTS INTERNATIONAL INC. Limited Warranty  
WhAT IS COvERED: Any defect in materials and workmanship.  
FOR hOW LONg: 2 years from date of purchase.  
WhAT WE WILL DO: If your product is defective and returned within 30 days  
after the date it was purchased, we will replace it at no charge to you. If  
returned after 30 days but within 2 years of the date of purchase we will  
repair it or, at our option, replace it at no charge to you.  
If we repair your product, we may use new or reconditioned replacement  
parts. If we choose to replace your product, we may replace it with a  
new or reconditioned one of the same or similar design. The repair or  
replacement will be warranted under our standard 2 year warranty.  
LIMITATIONS: IMPLIED WARRANTIES, INCLUDINg ThOSE OF FITNESS FOR A  
PARTICULAR PURPOSE AND MERChANTAbILITy (AN UNWRITTEN WARRANTy  
ThAT ThE PRODUCT IS FIT FOR ORDINARy USE), ARE LIMITED TO 2 yEARS  
FROM DATE OF PURChASE. WE WILL NOT PAy FOR LOSS OF TIME, INCONvE-  
NIENCE, LOSS OF USE OF yOUR PRODUCT OR PROPERTy DAMAgE CAUSED  
by yOUR PRODUCT OR ITS FAILURE TO WORk, OR ANy OThER INCIDENTAL  
OR CONSEqUENTIAL DAMAgES INCLUDINg PERSONAL INjURy.  
Some states do not allow limitations on how long an implied warranty  
lasts or the exclusion or limitation of incidental or consequential damages,  
so the above exclusions or limitations may not apply to you.  
Portable Power Source  
200 WATTS/400WATTS PEAK  
WhAT WE ASk yOU TO DO: To get warranty service for your product,  
you must provide proof of the date of purchase. Within 30 days of the  
date it was purchased, return your product to your place of purchase for  
immediate replacement. After 30 days, but before the end of the 2 year  
warranty period, you may return the product to the following address:  
Team Products International  
Owner’s Manual  
Attn: Customer Service Returns  
35 A Continental Drive  
Wayne, Nj 07470  
We suggest that you retain your original packing material in the event  
you need to ship your product. When sending your product include your  
name, address, phone number, proof of date of purchase, and a  
description of the operating problem. After repairing or replacing your  
product, we will ship it to your home or office within four weeks.  
WhAT ThIS WARRANTy DOES NOT COvER: Among oTher ThIngS ThIS  
WArrAnTy doeS noT cover defecTS reSulTIng from AccIdenTS,  
dAmAge WhIle In TrAnSIT To our ServIce locATIon, AlTerATIonS,  
unAuThorIzed repAIr, fAIlure To folloW InSTrucTIonS, mISuSe, fIre,  
flood, And AcTS of god. If your producT IS noT covered by our  
WArrAnTy, cAll our cuSTomer ServIce number AT (888) 231-4022 To  
deTermIne WheTher We WIll repAIr your producT And oTher repAIr  
InformATIon, IncludIng chArgeS. We, AT our opTIon, mAy replAce  
rATher ThAn repAIr your producT WITh A neW or recondITIoned  
one of The SAme or SImIlAr deSIgn. The repAIr or replAcemenT WIll  
be WArrAnTed for 2 yeArS.  
PMP200XL Models  
ThIS lImITed WArrAnTy IS The only one We gIve on your producT,  
And IT SeTS forTh All our reSponSIbIlITIeS regArdIng your producT.  
There Are no WArrAnTIeS WhIch exTend beyond The deScrIpTIon SeT  
forTh Above.  
©2006The Coleman Company, Inc. All rights reserved.  
STATE LAW RIghTS: This warranty gives you specific legal rights and you  
may also have other rights which may vary from state to state.  
COLEMAN® and  
are registered trademarks ofThe Coleman Company, Inc., used under license.  
Designed in the USA and custom-manufactured in China forTeam Products International Inc.  
Distributed byTeam Products International Inc., Mountain Lakes, NJ 07046.  
PMP200XL122205-191  
 
PMP200XL_122205M.indd 2-3  
12/22/05 9:09:47 AM  
Owner’s Manual  
PMP200XL Models  
Location of Controls  
1. ON/OFF Power Switch  
2. Green LED Indicator Light  
3. Protective Outlet Cover  
4. 110/120 Volt AC Outlet  
5. Cooling Fan  
5
Welcome  
This COLEMAN® product has been carefully engineered and manufactured  
to give you dependable operation. Please read this manual thoroughly before  
operating your new COLEMAN® product, as it contains the information you  
need to become familiar with its features and obtain the performance that will  
bring you continued enjoyment for many years. Please keep this manual on file  
for future reference.  
1
2
6
3
6. Red LED Indicator Light  
7. 12Volt DC Power Cord  
8. Clips For Power Cord  
9. Fuse Cover  
About COLEMAN® Inverters  
4
The new line of super-efficient COLEMAN® power inverters are innovative in  
design and have the highest surge capability in the industry.These extremely  
advanced, microprocessor controlled units run cooler and more reliable than  
any in their class.Their superior surge capability allows them to start even  
the most difficult loads, including color televisions,TV/VCR combinations,  
microwaves, refrigeration units, even small air conditioners!They also sport  
the highest efficiency available (up to 80%) which translates into longer running  
time and extended battery life. Inverters convert low voltage, direct current (DC)  
to 110/120-volt alternating current (AC). Depending on the model and its rated  
capacity, the inverters draw power either from standard 12-volt automobile and  
marine batteries or from portable high power 12-volt sources.  
10. 25Amp Fuse  
7
8
Getting Started  
When you turn on an appliance or a tool that operates using a motor or a tube,  
(such as a television), it requires an initial surge of power to start up.This surge  
of power is referred to as the “starting load” or “peak load.  
Once started, the appliance or tool requires less power to continue to operate.  
This is referred to as the “continuous load.You will need to determine how  
much power your appliance or tool requires to start up (peak power) and its  
continued operating power requirements (continuous load). Power consumption  
is rated either wattage (watts) or amperes (amps).This information is usually  
stamped or printed on most appliances and equipment. If this information is  
not indicated on the actual product, check the owners appliance or equipment,  
check the owners manual or contact the manufacturer to determine the power  
consumption. Be sure that the power consumption of the item you wish to  
operate is rated at 200 watts or less.  
9
Multiply: AMPS X 110/120 (AC voltage) = WATTS  
This formula yields a close approximation of the continuous load of the  
appliance. All COLEMAN® inverters are designed to automatically shut down in  
the event of a power overload. This protection feature prevents damage to the  
unit while testing items with ratings in the 200-watt range.  
F
U
10  
S
E
2
1
 
PMP200XL_122205M.indd 6-7  
12/22/05 9:09:47 AM  
Owner’s Manual  
PMP200XL Models  
CAUTION  
Source of Power  
The inverter is designed to operate from a 12-volt power source only.The unit  
will not operate from a 6-volt battery or a 24-volt battery. Do not attempt  
to connect the inverter to any other power nominal output voltage  
other than 12 volts or damage to the unit may occur. Any damage  
to the unit that occurs from operating the inverter from any power  
source greater than or less than 12 volts will automatically void the  
warranty.  
Most automobile and marine batteries will provide an ample power supply to  
the inverter for 30 to 60 minutes even when the engine is turned off. Actual time  
may vary depending on the age and condition of the battery and the power  
demand being placed on it by the equipment being operated.  
If you decide to use the inverter while the engine is off, we recommend that  
you start the engine every 30 to 60 minutes and let it run for approximately 10  
minutes to recharge the battery. It is also recommended that the device plugged  
into the inverter be turned OFF before starting the vehicle engine.  
• Do not attempt to extend or otherwise modify the 12-volt power cord attached  
to the inverter.  
Although it is not necessary to disconnect the inverter when starting the vehicle  
engine, it may momentarily cease to operate as the battery voltage decreases.  
When the inverter is not supplying power, it draws very low amperage from the  
battery. It is recommend that the inverter always be disconnected when not in  
use.  
110/120 volts can inflict serious injury, damage or death. Improper use of the  
inverter may result in property damage, personal injury or loss of life.  
Connecting the Inverter  
The inverter is equipped with a fused 12-volt power cord for connection to the  
power source.  
Blown Automotive Fuses  
Depending on the make and model of your automobile, running the power  
inverter near full capacity from your cigarette lighter socket may result in a  
blown automotive cigarette lighter fuse.This fuse will need to be replaced with  
the same type and size fuse. A blown automotive cigarette lighter fuse will not  
cause damage to your vehicle wiring.  
1. Make sure that the ON/OFF power switch located on the front panel of  
inverter is in the OFF(O) position.  
2. Connect the inverter to the power source by inserting the 12-volt power cord  
firmly into the cigarette lighter socket of your vehicle or other 12-volt DC  
power source.  
3.Turn the inverter power switch to the ON(-) position.The GREEN LED Indicator  
Light should illuminate to confirm that power is running to the inverter.  
Blown Inverter Fuses  
Your power inverter is equipped with a 25-amp spade type fuse. With  
reasonable care, it should not be necessary to replace this fuse. In general,  
most blown fuses are the result of reverse polarity hook up of the inverter to a  
12-volt power source (positive to negative and/ or negative to positive). If the  
fuse happens to blow, disconnect the appliance or equipment from the inverter  
immediately. Find the source of the problem, repair it and then install a new  
fuse of the same type and size located on the rear panel of the inverter.  
4. Make sure that the device you intend to operate is turned OFF. Plug the cord  
from the equipment into the AC outlet located on the front panel of the  
inverter.  
5.Turn the inverter power switch to the ON(-) position; then turn the  
equipment ON.  
Note  
Notes  
Always disconnect the power inverter from the 12-volt power source and make  
sure the inverter is turned OFF before replacing the fuse.  
The audible alarm may make a momentary “chirp” when the inverter is turned  
ON (-) or OFF(O).This same alarm may also sound when the inverter is being  
connected to or disconnected from the 12-volt power source.This is normal.  
Safety and Usage Precautions  
• If the GREEN LED Indicator Light blinks when you first turn the inverter ON(-),  
this may indicate an interruption of the power supply. Simply turn the inverter  
OFF(O) and remove the 12-volt power cord from the cigarette lighter socket (or  
other 12-volt power source). Firmly re-insert the 12-volt power cord, then turn  
the inverter ON(-) again. If this does not fix the problem, try using a different  
12-volt power source or check the cigarette lighter fuse.  
• For best operating results, place the inverter on a flat surface.  
• Keep the inverter dry. Do not expose the inverter to rain or moisture.  
• DO NOT operate the inverter if you, the inverter, the device being operated, or  
any surface that may come into contact with the inverter are wet. Water and  
other liquids can conduct electricity, which may lead to serious injury or death.  
3
4
 
PMP200XL_122205M.indd 8-9  
12/22/05 9:09:47 AM  
Owner’s Manual  
PMP200XL Models  
• Avoid placing the inverter on or near heating vents, radiators or other  
sources of heat. Do not place or use the inverter in direct sunlight. Ideal air  
temperatures should be between 50°F and 80°F.  
Television and Audio Suggestions  
Although all COLEMAN® inverters are shielded and filtered to minimize  
signal interference, some interference with your television picture may be  
unavoidable, especially with weak signals. However, here are some suggestions  
that may improve reception:  
• In order to properly disperse the heat generated from the inverter while it is  
operating, keep the inverter well ventilated. Keep the area surrounding the  
inverter clear while in use.  
• Make sure the television antenna produces a clear signal under normal  
operating conditions (at home plugged into a standard 110/120- volt AC  
outlet). Also, ensure that the antenna cable is properly shielded and/or good  
quality.  
• Do not use the inverter near flammable materials. Do not place the inverter in  
areas such as battery compartments where fumes or gases may accumulate.  
• Change the positions of the inverter, antenna cables and the television power  
cord.  
Inverter Protection Features  
• Short Circuit Protection.The inverter will automatically shut down until  
short is removed.  
• Isolate the television, its power cord and antenna cables from the 12-volt  
power source by running an extension cord from the inverter to the television  
set.  
• Low Voltage Alarm. An alarm will sound when the voltage from the battery  
discharges to 10.5 +/- 0.5 volts DC.This is an indication that the battery needs  
to be recharged.  
• Coil the television power cord and the input cables running from the 12-volt  
power source to the inverter.  
• Over Voltage Protection.The RED LED Indicator Light will illuminate and  
the inverter will automatically turn itself off when the input exceeds 16.5 +/- 1  
volt DC.  
• Attach an AC interference filter or similar product between the inverter and  
the television power cord.These filters are available at most electronic supply  
stores including Radio Shack.  
• Under Voltage Protection. The RED LED Indicator Light will illuminate and  
the inverter will automatically turn itself off when the input is less than 10.0+/-  
0.5 volts DC.  
Note  
Inexpensive sound systems may emit a “buzzing” sound when operated with  
an inverter.This is due to the inadequate filters in the sound system.There is  
no solution to this problem other than purchasing a sound system with a higher  
quality power supply.  
• Overload Protection.The RED LED Indicator Light will illuminate and  
the inverter will automatically turn itself off when the continuous draw of  
the equipment being operated exceeds 200 watts or the surge draw of the  
equipment exceeds 400 watts.  
Thermal Protection. The RED LED Indicator Light will illuminate and the  
inverter will automatically turn itself off when the circuit temperature exceeds  
130°F.  
How Power Inverters Work  
Power inverters convert low voltage DC (direct current) power to 110/120-volt  
AC (alternating current) household power.This conversion process thereby  
allows you to use household products, power tools, and other electronic  
products away from normal AC power sources (standard 110/120V wall outlets).  
Notes  
The inverter is equipped with a cooling fan, which is designed to run  
continuously while the inverter is operating. Automatic shut down of the unit  
caused by high circuit temperatures will occur when the cooling fan is unable  
to maintain a cool enough temperature for safe operation.  
Depending on the model and its rated capacity, inverters can draw power  
either from standard 12-volt automobile and marine batteries or from portable  
high power 12-volt power sources.The waveform that is generated by this  
conversion is a “modified sine wave.The modified sine wave produced by our  
inverters has a root square mean (RMS) voltage of 110/120 volts, which is the  
same as standard household power.  
• In the event of automatic shut down or a continuous audible alarm, turn the  
inverter power switch to the OFF(O) position until the source of the problem  
has been determined and resolved.  
The majority of AC voltmeters are calibrated for RMS voltage under the  
assumption that the measured waveform will be a pure sine wave.Therefore,  
these meters will not read the RMS modified sine wave voltage correctly.  
5
6
 
PMP200XL_122205M.indd 10-11  
12/22/05 9:09:48 AM  
Owner’s Manual  
PMP200XL Models  
They will read about 20 to 30 volts too low.To accurately measure the output  
voltage of the inverter, use a true RMS reading voltmeter such as a Fluke 87,  
Fluke 8060A, Beckman 4410,Triplett 4200 or any voltmeter identified as a “true  
RMS” modified sine wave.  
SPECIFICATION:  
Max. Continuous Power ....................................................200 Watts  
Surge Capability (Peak Power) ..........................................400 Watts  
No Load Current Draw ............................................................<0.3A  
Waveform ..........................................................Modified Sine Wave  
Input Voltage Range ........................................................11-15 VDC  
AC Receptacle ......................................... 110/120V AC 3 prong rounded  
Fuse ................................................................ 25 amp (spade type)  
In Review  
• Never attempt to operate the inverter from any other power source other than  
a 12-volt battery.  
The inverter is designed to be connected to the power source with the supplied  
12-volt power cord. Do not attempt to modify the power cord in any way.  
• When connecting and using the inverter, make sure that the inverter is  
positioned far away from any potential source of flammable fumes or gases.  
Dimensions ............................................. 3.6”(L) x 4.1”(W) x 6.9”(H)  
92(L) x 105(W) x 175(H) /mm  
• Make certain that the power consumption of the equipment you wish to  
operate is compatible with the capacity of the inverter. Do not exceed 200-  
watts.  
Weight ................................................................................ 1.144 lbs (0.52 kgs)  
Power Cord Cable ............ 14 AWG (Black) with cigarette plug x 1 pc.  
• When attempting to operate battery chargers, monitor the temperature of the  
battery charger for approximately 10 minutes. If the battery charger becomes  
abnormally warm, disconnect it from the inverter immediately.  
WARNING:  
The wattage output from your 12 Volt power port may vary depending on the  
make and model of your vehicle. Please check your owners manual.  
• Use only 25 amp spade type fuses for the inverter.  
• When operating the inverter with an automobile or marine battery, start the  
engine every 30 to 60 minutes and let it run for approximately 10 minutes to  
recharge the battery.  
Questions?  
• In the event of a continuous audible alarm or an automatic shut down of the  
unit, turn the inverter OFF immediately. Do not turn the inverter ON again until  
the source of the problem has been identified and corrected.  
If you have any questions about this product, please contact our Customer  
Service Department at (888) 231-4022, 9 AM to 5 PM EST, Monday through  
To avoid battery drain, always disconnect the inverter when not in use.  
• Do not expose the inverter to rain or moisture.  
• Avoid placing the inverter near sources of heat or in direct sunlight.  
• While in use, make sure that the inverter is properly ventilated.  
• For best operating results, make sure the unit is placed on a flat surface.  
Note  
If you would like to purchase battery clips for this inverter, they are available for  
purchase through our Customer Service Department at: 1-888-231-4022  
8
7
 
PMP200XL_122205M.indd 12-13  
12/22/05 9:09:48 AM  
Owner’s Manual  
PMP200XL Models  
Troubleshooting  
Troubleshooting  
PROBLEM: Low or No Output Voltage  
Reason  
PROBLEM:TV Interference  
Reason  
Solution  
Solution  
Electrical interference from  
the inverter.  
Add an AC interference filter on  
to theTV power cord. Refer  
toTV and audio section of  
this manual.  
Poor contact with  
lighter socket or  
battery terminals.  
Unplug and reinsert 12  
volt plug or reattach  
battery clips.  
Using incorrect type of  
voltmeter to test  
output voltage.  
Use true RMS reading meter.  
PROBLEM: Low Battery Alarm On AllTheTime  
Reason  
Solution  
Input voltage below10.5 0.5 volts.  
Keepinputvoltageabove10.5 0.5  
volts to maintain regulation.  
PROBLEM: Red LED On  
Reason  
Solution  
Poor or weak  
Recharge or  
Battery voltage below  
10.0 0.5 volts.  
Recharge or replace battery.  
battery condition.  
replace battery.  
Inadequate power being  
delivered to the inverter  
or excessive voltage drop.  
Check condition of cigarette  
lighter socket. Clean or  
replace if necessary  
Equipment being operated  
draws too much power.  
Use a higher capacity inverter  
or do not use this equipment.  
PROBLEM:TV Does Not Work  
Inverter is too hot (thermal  
shutdown mode).  
Allow inverter to cool.  
Check for adequate ventilation.  
Reduce the load on the  
inverter to rated continuous  
power output  
Reason  
Solution  
TV does not turn on.  
Try turning the inverter  
ON/OFF/ON.  
ContactTV manufacturer for  
start up surge and power  
consumption.  
Unit may be defective.  
See Warranty and call  
Customer service at  
1-888-231-4022.  
A larger inverter may  
be required.  
10  
9
 
PMP200XL_122205M.indd 14-15  
12/22/05 9:09:50 AM  
Owner’s Manual  
 
PMP200XL_122205M.indd 16-17  
12/22/05 9:09:51 AM  

Toastmaster Coffeemaker TCM14B User Manual
Toshiba Projector TDP T98 User Manual
TP Link Network Router TL WR941N User Manual
Tripp Lite Network Cables N201 007 WH User Manual
Troy Bilt Tiller 12077 User Manual
True Manufacturing Company Freezer TDC 47 User Manual
UNICOM Electric Network Card ETP 20028T User Manual
Uniflame Gas Grill GBC983W C User Manual
Victory Refrigeration Refrigerator RS 3N S7 User Manual
Vidikron Projector Vision 20 User Manual