TABULAR DATA SHEET
Outdoor Split System Heat Pump 1.5 Thru 5 Tons
MODELS: THJF18* THRU 60
14.5 SEER – R-410A, 1 PHASE
Physical and Electrical Data
THJF18
S41S3
THJF24
S41S3
THJF30
S41S3
THJF36
S41S3
THJF42
S41S3
THJF48
S41S3
THJF60
S41S3
MODEL
Unit Supply Voltage
208-230V, 1 60Hz
Normal Voltage Range 1
Minimum Circuit Ampacity
Max. Overcurrent Device Amps 2
187 to 252
23.7
11.9
20
17.6
30
17.3
30
26.1
45
28.8
50
35.3
60
40
Min. Overcurrent Device Amps 3
Compressor Type
15
Scroll
9.0
20
Scroll
13.4
58.3
No
20
Scroll
12.8
64.0
No
25
Scroll
17.9
96.7
No
30
Scroll
19.8
115.0
No
30
Scroll
28.8
115.0
No
40
2-Stage Scroll
35.3
118.0
No
Rated Load
Compressor
Amps
Locked Rotor
48.0
No
Crankcase Heater
Factory External Discharge Muffler
Factory External Check Valve
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
HS Kit Required with TXV 4
No
No
No
No
No
No
No
Fan Motor Amps
Rated Load
0.7
0.8
1.3
1.3
1.3
1.3
1.3
Fan Diameter Inches
24
22
24
24
24
24
24
Rated HP
1/10
825
2000
15.72
1
1/8
1/4
1/4
1/4
1/4
1/4
Fan Motor
Coil
Nominal RPM
Nominal CFM
Face Area Sq. Ft.
Rows Deep
1075
2000
19.17
1
850
3900
23.58
1
850
3900
23.58
1
850
3900
23.58
1
850
3800
23.58
2
850
3800
23.58
2
Fin / Inches
22
22
22
22
22
18
18
Liquid Line Set OD (Field Installed)
Vapor Line Set OD (Field Installed)
Unit Charge (Lbs. - Oz.) 5
Charge Per Foot, Oz.
Operating Weight Lbs.
3/8
3/8
3/8
3/8
3/8
3/8
3/8
3/4
3/4
3/4
3/4
7/8
7/8
1-1/8
14 - 2
0.75
290
6 - 15
0.62
145
7 - 14
0.62
145
9 - 14
0.62
176
10 - 9
0.62
193
10 - 14
0.67
198
14 - 2
0.67
248
1. Rated in accordance with ANSI/AHRI Standard 110-2002, utilization range “A”.
2. Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.
3. Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.
4. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.
5. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet,
add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.
All dimensions are in inches. They are subject to change without notice.
Certified dimensions will be provided upon request.
C
Dimensions
(Inches)
Refrigerant Connection
Service Valve Size
Unit
Model
A1
28
40
40
40
40
40
40
B
C
Liquid
Vapor
34
29
34
34
34
34
34
34
29
34
34
34
34
34
18
24
30
36
42
48
60
A
3/4”
3/8”
7/8”
B
1. Including Fan Guard.
MAC-222
ECN 5287-MA 121005
|