MIL-SM8002TG
9 Port 10/100/1000BASE-T
Two Combo 1000BASE-X SFP
Ports
Advanced Managed Switch
Quick Installation Guide
Rev.A
09-MAY2006
Introduction
The product is a multi-port switch that can be used to build high-performance switched
indoor or protected outdoor networks. It provides wire-speed, Gigabit Ethernet switching
function that allows high-performance, low-cost connection. The Switch features a
store-and-forward switching and it can automatically learn and store source address in an
8K-entry MAC address table.
Package Contents
Unpack the contents of the switch and verify them against the checklist below.
¢
¢
¢
¢
¢
Managed Switch unit
Power Cord
Four Rubber Feet
RS-232 cable
User Manual
If any item is missing or damaged, please contact your local dealer for service.
1
Hardware Description
Physical Dimension
The physical dimensions of the switch is 217mm(W) x 140mm(D) x 43mm(H)
Desktop Installation
Mount the switch on a desired space by either using wallmount brackets of rubber feet.
Make sure there is enough clearance around the Switch to allow attachment of cables,
power cord and air circulation.
Power On
Connect the power cord to the power socket on the rear panel of the Switch. The other
side of power cord connects to the power outlet. The internal power works with AC in the
voltage range 90-240VAC, frequency 50~60Hz. Check the power indicator on the front
panel to see if power is properly supplied.
2
Initial Setup
Login in the Console Interface
Use serial cable provided in the package to pre-configure the IP settings. When the
connection between Switch and PC is ready, turn on the PC and run a terminal emulation
program or Hyper Terminal and configure its communication parameters to match the
following default characteristics of the console port:
Baud Rate: 9600 bps
Data Bits: 8
Parity: none
Stop Bit: 1
Flow control: None
The settings of communication parameters
After finished the parameter settings, click “OK“. When the blank screen shows up, press
Enter key to bring out the login prompt. Key in the “root“(default value) for the both User
3
name and Password (use Enter key to switch), then press Enter key and the Main Menu
of console management appears. Please see below figure for login screen.
Console login interface
IP/Subnet/Gateway Setup
MIL-SM8002TG is shipped with a default IP of 192.168.1.77. In order to set up a customer
specific IP/Subnet/Gateway Use Main menu – Type: “menu” – Select System
Configuration – IP Configuration
In the IP configuration window please choose the following:
1. DHCP: disable or enable the DHCP client function. When DHCP function is enabled
you don’t need to assign the IP address and subnet mask. The system will be
4
assigned the IP address from the local DHCP server.
2. IP Address: assign the switch IP address. The default IP is 192.168.16.1.
3. Subnet Mask: assign the switch IP subnet mask.
4. Gateway: assign the switch gateway. The default value is 192.168.16.254.
5. DNS1: Optionally set up Domain Name Server
6. DNS2: Optionally set up a backup for DNS1. When the DNS1 cannot function, the
DNS2 can replace DNS1 immediately.
7. Select <Save> action to save the configuration.
[NOTE] Always restart the switch after finished the setup.
Continue with web-based management for additional setup.