The Avtec EcoArch 2000 Series
Model Number1
Hood Section Dimensions2
Application
CFM/Ft3
Available length of 48”to 192”
x 30”high
EA2-DDLLL-30
600˚F
150
Available length of 48”to 192”
x 30”high
EA2-DDLLL-30
400˚F
130
1 DD = Depth in inches, LLL=Length in inches, 30=Height in inches.
Example: EA2-54120-30 stands for a 54”deep x 120”long x 30”high unit.
2 For hood lengths longer than 192”, multiple sections can be grouped together.
3 Minimum CFM may vary based on cooking equipment application.
The Most Energy Efficient
Ventilation System.
Constructed of High Grade Non-Corrosive
Stainless Steel
The Avtec EcoArch combines
both an economical and
environmentally safe solution for
the need for high-quality, cost-
effective ventilation performance
in today’s foodservice kitchens.
Up to 40% Annual Energy Savings
Using Exclusive Design Features
Exclusive Aerodynamic Arch – Dramatically reduces the amount of turbulence
within the canopy reservoir. About 70% of the contaminated air is exhausted
immediately out of the reservoir.
The EcoArch ventilation system
addresses the growing need
to reduce the amount of
High Velocity Exhaust Slot – The higher rate of speed at the slot in addition to its
location at the top of the canopy effectively removes the contaminated air working
in conjunction with the arch top.
conditioned air from a kitchen
space. The combination of the
patent pending arch top and
the front mounted high velocity
exhaust slot reduces the amount
of exhausted CFM by 45%
compared to traditional CFM rates.
This translates into an annual
electric and gas savings
Easier and Safer Removal of Filter Medium
Unlike tradition rear filter locations, EcoArch exhaust plenum and filters are located
in the front of the hood eliminating the need to climb on top of cooking equipment
for daily removal and cleaning.
Recessed Fluorescent Light Fixtures
EcoArch comes standard with recessed fluorescent light fixtures to maximize
light foot candles at the cooking surfaces with the least amount of energy
consumption.
of up to 40%.
Sample Energy Savings
Now that’s maximizing your
energy and cost savings!
150 cfm/ft (EcoArch) vs. 250 cfm/ft (traditional unit)
12’Hood, 400°F, Gas & Electric, Based on 2006 Utility Rates
Location
cfm/ft Annual Gas Annual Electric Total Energy Annually Savings %
New York, NY
New York, NY
Total Savings
Atlanta, GA
250
150
$5425
$3255
$2170
$3728
$2237
$1491
$1364
$828
$536
$943
$571
$371
$6789
$4083
$2706
$4671
$2808
$1863
40%
250
150
Atlanta, GA
Total Savings
40%
EAVS-2000S-0907
|