Unified Brands Ventilation Hood 2000 Series User Manual

The Avtec EcoArch 2000 Series  
Model Number1  
Hood Section Dimensions2  
Application  
CFM/Ft3  
Available length of 48”to 192”  
x 30”high  
EA2-DDLLL-30  
600˚F  
150  
Available length of 48”to 192”  
x 30”high  
EA2-DDLLL-30  
400˚F  
130  
1 DD = Depth in inches, LLL=Length in inches, 30=Height in inches.  
Example: EA2-54120-30 stands for a 54deep x 120long x 30high unit.  
2 For hood lengths longer than 192, multiple sections can be grouped together.  
3 Minimum CFM may vary based on cooking equipment application.  
The Most Energy Efficient  
Ventilation System.  
Constructed of High Grade Non-Corrosive  
Stainless Steel  
The Avtec EcoArch combines  
both an economical and  
environmentally safe solution for  
the need for high-quality, cost-  
effective ventilation performance  
in today’s foodservice kitchens.  
Up to 40% Annual Energy Savings  
Using Exclusive Design Features  
Exclusive Aerodynamic Arch – Dramatically reduces the amount of turbulence  
within the canopy reservoir. About 70% of the contaminated air is exhausted  
immediately out of the reservoir.  
The EcoArch ventilation system  
addresses the growing need  
to reduce the amount of  
High Velocity Exhaust Slot – The higher rate of speed at the slot in addition to its  
location at the top of the canopy effectively removes the contaminated air working  
in conjunction with the arch top.  
conditioned air from a kitchen  
space. The combination of the  
patent pending arch top and  
the front mounted high velocity  
exhaust slot reduces the amount  
of exhausted CFM by 45%  
compared to traditional CFM rates.  
This translates into an annual  
electric and gas savings  
Easier and Safer Removal of Filter Medium  
Unlike tradition rear filter locations, EcoArch exhaust plenum and filters are located  
in the front of the hood eliminating the need to climb on top of cooking equipment  
for daily removal and cleaning.  
Recessed Fluorescent Light Fixtures  
EcoArch comes standard with recessed fluorescent light fixtures to maximize  
light foot candles at the cooking surfaces with the least amount of energy  
consumption.  
of up to 40%.  
Sample Energy Savings  
Now that’s maximizing your  
energy and cost savings!  
150 cfm/ft (EcoArch) vs. 250 cfm/ft (traditional unit)  
12’Hood, 400°F, Gas & Electric, Based on 2006 Utility Rates  
Location  
cfm/ft Annual Gas Annual Electric Total Energy Annually Savings %  
New York, NY  
New York, NY  
Total Savings  
Atlanta, GA  
250  
150  
$5425  
$3255  
$2170  
$3728  
$2237  
$1491  
$1364  
$828  
$536  
$943  
$571  
$371  
$6789  
$4083  
$2706  
$4671  
$2808  
$1863  
40%  
250  
150  
Atlanta, GA  
Total Savings  
40%  
 
EAVS-2000S-0907  

Teac CD Player PD 501HRCD User Manual
Technics Stereo System SL PD667 User Manual
Timex Clock T025 User Manual
Toshiba Air Conditioner RAV SP180CT UL User Manual
Toshiba Flat Panel Television ZP38 Series User Manual
TP Link Network Card TL PA4020 User Manual
TP Link Network Card TL WN851ND User Manual
Uniden Cordless Telephone XS210 User Manual
Varimixer Mixer W20SF User Manual
Wayne Septic System 330102 001 User Manual