KEY FEATURES
BATTERY INSTALLATION
(See diagram below)
• No probe cover needed
• Probe can be wiped clean with water
or alcohol
1. Replace the battery when
the “low battery” warning
symbol appears.
• Each temperature reading takes only 1
second
2. Slide the battery compartment lid off.
• A second temperature reading can be
taken after just 5 seconds
3. Insert one 3-volt CR-2032 lithium
• 512 temperature scanning sequences per
second ensure reliable accuracy
battery with the anode (+) facing up.
• Ergonomic design makes the thermometer
comfortable and easy to use
4. Replace the battery compartment lid by
sliding it forward.
• Stores and recalls last 10 readings
• Small and lightweight design makes it
ideal for home use and traveling
• Powers off automatically after one minute
of non-use to ensure a long battery life for
at least 5,000 measurements
• Easy to read LCD display
• Temperature shown in Fahrenheit (F) or
Celsius (C)
The Ear Thermometer is a Personal Care
Product and cannot be returned to the retailer.
All exchange and refund requests should be
directed to the BébéSounds® Help Desk
at 1-888-232-6476
Mon-Fri from 9:00AM – 5:00PM EST
4
5
into the ear to allow the
probe tip to continuously
scan the ear canal. This
will ensure an accurate
temperature measurement
(See Fig. 4). After one
second release the
INSTRUCTIONS FOR USE
1. Press and realease the
POWER/SCAN button
and the system will start
Figure 4
Figure 1
its self-testing cycle
(See Fig. 1).
POWER/SCAN button
for a temperature reading.
2. Once the self-testing is
completed, the display
will show the last temper-
ature recorded. (See Fig.
2). This indicates that the
thermometer is ready for
you to use.
Figure 2
5. A beep will indicate the
end of the temperature
measurement. (See Fig. 5).
Remove thermometer from
ear canal and view the
temperature.
Figure 5
3. Press the POWER/SCAN
button without releasing
it so it will perform the
automatic scanning
6. To change the reading from Celsius to
Fahrenheit, press the POWER/SCAN
button without releasing it and then
press the MEM button.
Figure 3
sequences. The word Lo
may appear indicating
the temperature
7. A smiling face will
registering is lower than
93.2°F/34°C (See Fig. 3).
appear in the display to
indicate a temperature
Figure 6
lower than 100.4°F/38°C
4. Keeping the POWER/SCAN button
depressed, insert the probe into the ear
canal. The probe must be inserted well
6
7
while a frowning face
accompanied by one
long and two short beeps
will indicate a
temperature higher than
100.4°F/38°C
simply press the MEM button. The
memory symbol (top left corner), the
number of the reading and the tempera-
ture reading will appear on the display
(See Fig. 11).
Figure 7
(See Figs. 6 & 7).
11. To get the most precise temperature
reading wait five seconds before taking
a temperature again.
8. The thermometer’s
temperature range is
Figure 8
Figure 9
between 93.2°- 109.4°F
and 34°- 43°C. A Lo
reading appears when
the temperature measured
is lower than 93.2°F/34°C,
12. The temperature will vary between both
ears so try to take the temperature from
the same ear each time.
while a Hi reading appears when the
temperature measured is higher than
109.4°F/43°C (See Figs. 8 & 9).
9. If the ambient temperature
is outside the thermome-
Figure 10
ter’s range (see Technical
Specifications), “Err” will
appear in the display
(see Fig. 10).
The Ear Thermometer is a Personal Care
Product and cannot be returned to the retailer.
All exchange and refund requests should be
directed to the BébéSounds® Help Desk
at 1-888-232-6476
10. The Ear Thermometer
stores and recalls the last
10 temperature readings.
Figure 11
Mon-Fri from 9:00AM – 5:00PM EST
To recall prior readings
8
9
UNDERSTANDING THE
SYMBOLS
CARE AND CLEANING
1. The ear thermometer is a delicate
electronic device. Although the probe
is waterproof, the body of the
Degrees of temperature
Celsius
thermometer is not. Therefore, to ensure
proper functioning, avoid direct contact
of the body of the thermometer with
water or other liquids.
2. Clean the probe with a soft cloth
moistened with either water or alcohol.
Clean the body of the thermometer with
a soft dry cloth. Never use an abrasive.
Fahrenheit
Temperature is being scanned
3. Avoid touching the probe with your
fingers.
Memory symbol and number of
the recorded reading
4. Do not expose the thermometer to direct
sunlight.
Low battery warning
5. Keep out of the reach of children and in
the storage case when not in use.
The optimal storage temperature is
between 4°~122°F/-20°~50°C.
Smiling face indicating
temperature lower than
100.4°F/38°C
6. The ear thermometer is designed for
taking temperatures from the ear canal
only. Do not use it to take rectal, oral,
or armpit temperatures.
Frowning face indicating
temperature higher than
100.4°F/38°C
7. Do not disassemble the thermometer.
10
11
NOTE: According to extensive clinical
examinations, the temperature readings
given by an ear thermometer are equivalent
to those given by its oral counterparts.
NOTE: If you believe your thermometer
is defective or otherwise not operating
properly, please check the battery first.
If the thermometer is still not operating
properly or if you are having any other
technical problems, please contact:
Use of this ear thermometer should not
replace a visit to your doctor.
Unisar Inc.
TROUBLESHOOTING
1. Consistent low temperature readings
15 West 36th Street
New York, NY 10018
1-888-232-6476
a. The probe is not positioned properly in
the ear canal. The tip of the probe must
be snug and fully seated against the
opening of the ear canal. Failure to
properly position the probe may lead to
a low temperature reading.
b. The waterproof lens is dirty. Clean the
lens with a soft cloth moistened with
water or alcohol.
TECHNICAL SPECIFICATIONS
• For household use only
• Temperature readings are to the nearest
0.1°F or °C
• Temperature measurement range:
93.2° ~ 109.4°F/34°C ~ 43°C
• Ambient operating environment:
60.8 ~ 104°F (16° ~ 40°C)
• Ambient storage environment:
-4° ~ 122°F/-20° ~ 50°C
2. The measurement is out of the range
of the ear thermometer
a. Switch the ear thermometer on before
positioning it in the ear. Please
properly position the ear thermometer
in the ear canal and then repeat the
measurement.
3. Low battery warning
a. Battery needs to be replaced.
See Battery Installation section of the
• Laboratory accuracy against an infrared
reference source:
95°~102.2°F/35° ~ 39°C: +/- 0.4°F/0.2°C
less than 96.8°F/36°C: +/- 0.5°F/0.3°C
greater than 102.2°F/39°C: +/-0.5°F/0.3°C
• Requires one 3-volt CR-2032 battery
(included)
• Equipment is not category AP/APG
manual.
12
13
LIMITED PRODUCT WARRANTY
APPLIED STANDARDS AND
APPROVALS
The BébéSounds® Ear Thermometer,
distributed by Unisar Inc., has a limited
warranty against defects for a period of
three years from the original purchase date.
Battery life or damage due to misuse or
abuse are excluded from this warranty.
FDA approved. For home use only.
This product conforms to the provisions of
the EC directive MDD(93/42/EEC).
The following standards apply to design
and/or manufacturing of the products:
• ASTM E 1965-98: Standard Specification
for infrared thermometers for intermittent
determination of patient temperature.
In-Warranty Procedure
In the event service is required due to
defect or malfunction during the warranty
period, Unisar Inc. will replace or repair the
product under warranty. The repair or
replacement of the defective item will be
free of charge. Repair or replacement of
the defective item is subject to verification
of the malfunction or defect when delivered
to:
• EN 980:1997: Graphical symbol for
use in the labeling of medical devices.
• EN 60601-1: Medical electrical
equipment – Part 1: General require-
ment for safety.
• EN60601-1-2: Medical electrical
equipment – Part 2: Collateral stan-
dard: Electromagnetic compatibility –
Requirements and tests.
Unisar® Service Center
15 West 36th Street
New York, NY 10018 USA
Please enclose dated proof of purchase with
your return.
14
15
The Ear Thermometer is a Personal Care
Product and cannot be returned to the retailer.
All exchange and refund requests should be
directed to the BébéSounds® Help Desk
at 1-888-232-6476
Mon-Fri from 9:00AM – 5:00PM EST
Unisar Inc.
15 West 36th Street
New York, NY 10018
1-800-233-1196
visit us at
|